Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

AutoPIPE

Showing 133 of 203

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
over 1 year ago in AutoPIPE / Modelling 0 Future consideration

Carbon Steel Flange Material

It would be extremely useful to add additional carbon steel flange material to the database drop down list. In my experience, the majority of the pipelines are comprised of the materials shown below and their flanged equivalent. Please add the fol...
4 months ago in AutoPIPE / Analysis 0 Needs review

Wind load acc. to EN 1991-1-4 (Wind)

In the European Union we design wind loads acc. to EN 1991-1-4 (Wind), hence it would be nice if wind loads are implemented as in other pipe stress analysis programs.
over 1 year ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Support Detail Fig # and Allowable Support Load Ratings

Ensuring support info (gaps, friction, stiffness) is correct and reviewing support results are some of the more time consuming tasks. It would be very handy to be able to set up a library of support detail figure numbers with allowable load ratings.
about 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration

Reference Loads - Results Database

Currently, AutoPIPE does not have the option to export reference loads to a .mdb file. I want to be able to easily compare the Reference Loads to their allowable. This is most handy when you have radial nozzles. Please include the allowable loads ...
about 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

When exporting a model, the user should have the ability to select which nodes are exported based on the type of element it represents.

When creating stress isometric drawings, my team typically exports a .dxf file of the AutoPIPE Model. We are only concerned with nodes that represent support locations, however, there is no option to export only support nodes. Having this option a...
over 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Total Computing Power

I noticed that Autopipe uses a limited amount of computer power. In a time-history analysis with a modal frequency of 400hz on a relatively small model it took about 30min using only 6 to 9% of the computer's processing power. An improvement in pr...
4 months ago in AutoPIPE / Analysis 3 Needs review

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
over 1 year ago in AutoPIPE / UI 0 Needs review

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
8 months ago in AutoPIPE / Analysis 0 Future consideration