Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 49

Fix the Load Sequencing for Snow Load

The help file states the following for snow load analysis: Limitation Currently, AutoPIPE only considers snow loading as linear analysis. Load sequencing does not apply to snow loads and such results should not be considered. For analysis sets tha...
about 1 year ago in AutoPIPE / Analysis 0 Needs review

Model new piping geometry based on newly established local coordinate system instead of Global coordinate system

Use Case: If The entire model is using plant coordinates thus causing the entire system to be off AutoPIPE's global axis. Then, if the user needs to add new piping geometry it is very difficult to model in AutoPIPE using global coordinates. Users ...
about 1 year ago in AutoPIPE / Modelling 0 Needs review

Add China Electric Power industry standard DL/T 5366

At present, the pipeline stress calculation specification is selected as the American standard, whether it is considered to refer to the Chinese standard DL/T 5366-2014. If there is no reference to this standard, then please ask whether this stand...
about 1 year ago in AutoPIPE / Code 0 Needs review

Copy & pasting pipe components with existing soil Id's are not updated with new Soil Id names

Open PipeSoil.apc Notice the Soil id currently in the model. Select all of the model. Paste to any location after pasting, notice the number of Soil Id's has doubled. Recommend when coping / pasting pipe node points with existing Soil Id's that th...
about 1 year ago in AutoPIPE / Modelling 0 Needs review

Looking for an update to Import/Export the file from UG-Nx to Autopipe or Vice versa. Currently there is no common format's available which will support both the softwares.

Looking for an update to Import/Export the file from Auto-Pipe to UG-Nx or Vice versa. Currently there is no common format's available which will support both the software's.
about 1 year ago in AutoPIPE / AutoPIPE Pipe Stress 4 Needs review

Display response spectrum acceleration results using the 'interactive' results viewer (showing deformed model and acceleration values)

The AutoPIPE 'interactive" menu has a way to display displacement results and filter results. Presently, the acceleration results in a response spectrum analysis are only viewable from the text result files or excel reports. Having a GUI accelera...
over 1 year ago in AutoPIPE / UI 0 Needs review

StressISO Title Block Automatic Fill

Add the ability to populate the title block information: dates, line number, etc.
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

User to select spring from list of springs returned by Spring hanger analysis command

After running a hanger selection analysis with the currently defined hanger analysis parameters, 1 or more possible spring hangers that meet the criteria are reported, starting with the longest range and highest spring rate and finishing with the ...
over 1 year ago in AutoPIPE / Analysis 1 Needs review

Include UID number in "Result" mdb output.

In our work process we create PCF file using S3D. After analyzing data inside Autopipe we would like to export some of the analyzed data from Autopipe and import back to S3D. Easiest way to achieve that would be by using UID number of the analyzed...
9 months ago in AutoPIPE / Reporting 0 Needs review

Specifying sub-report item under batch run by ntl files

I want to customize the output report items for an automation process. I'm building the system by ntl file. The dat file can customize them but the ntl file cannot.
over 1 year ago in AutoPIPE / Reporting 1 Needs review