Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Reporting

Showing 22 of 232

User Having to Re-import .CMB File After Saving .APC File

When saving APC files, the code/non-code combinations get reset to default by AutoPIPE. User has to go though an extra step of re-importing the relevant .CMB file after saving the APC file. If there is a way to have AutoPIPE maintain the already s...
8 days ago in AutoPIPE / Reporting 0 Needs review

Exporting .DGN of Code Stresses Color Graphics

Adding an option to export the Maximum Code Stresses Color Graphics in .DGN format. The user can utilize this feature to present the code stresses in a more visual way in Navisworks.
about 2 months ago in AutoPIPE / Reporting 0 Needs review

Support Report: Remove all global results from Local columns

For V-stops and Hanger support types, the Support report prints global values as local values. Example, see attached image. Notice the Global axis direction is different from the indicated pipe's local axis direction. Next notice the support's Loc...
2 months ago in AutoPIPE / Reporting 0 Needs review

Add design margins to piping loads being sent to structural

When it comes to exporting pipe support loads from AutoPIPE to STAAD, PipeLINK is an effective tool. While PipeLINK has most of the necessary functionality, there is a lack in the ability to add a Design Margin to the pipe support loads sent from ...
11 months ago in AutoPIPE / Reporting 4 Needs review

Bring back Access database export

Removing the Access database export has killed our work flow and we can not find a work around using SQLite.
about 2 months ago in AutoPIPE / Reporting 1 Will not implement

Support Results grids local direction should be user friendly and consistent

Open the results grids, select the support tab, and locate the columns for LocalDir1 - Gap3. Quick what does this refer to: pipe local axis, support local axis? Is this direction consistent across all of the support types (see attached image of Su...
almost 2 years ago in AutoPIPE / Reporting 1 Needs review

Include option to extract displacement results (at node points) in local axes

Nodal displacement results in local axes would be immensely useful. I use AutoPIPE for onshore pipelines which are not straight & reviewing the displacement locally is often needed.
4 months ago in AutoPIPE / Reporting 1 Needs review

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
about 1 year ago in AutoPIPE / Reporting 1 Future consideration

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
6 months ago in AutoPIPE / Reporting 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
6 months ago in AutoPIPE / Reporting 2 Needs review