Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 128

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
7 months ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
7 months ago in AutoPIPE / Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
7 months ago in AutoPIPE / Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
7 months ago in AutoPIPE / Reporting 2 Needs review

Add capability to model 2 springs in series

Spring hanger arrangement, see attachment.
over 1 year ago in AutoPIPE / Modelling 0 Needs review

Model new piping geometry based on newly established local coordinate system instead of Global coordinate system

Use Case: If The entire model is using plant coordinates thus causing the entire system to be off AutoPIPE's global axis. Then, if the user needs to add new piping geometry it is very difficult to model in AutoPIPE using global coordinates. Users ...
over 1 year ago in AutoPIPE / Modelling 0 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
7 months ago in AutoPIPE / Reporting 0 Needs review

LOCATION SADDLES

On many occasions, we find horizontal vessels that can be suspended from the ceiling. saddles should be able to be placed on the top of the equipment and should be calculated in traction and not compression.
about 1 year ago in AutoPIPE Vessel 0 Needs review

Add spanish wind code CTE DB-SE-AE for

For projects in Spain, engineering companies request the Spanish wind code CTE DB-SE-AE. The Spanish wind code that is implemented in autopipe vessel is old.
about 1 year ago in AutoPIPE Vessel 0 Needs review

Color plot: Connected Segments

Provide a color map based on the Connected Segments (Select > Segments > Connected Segments). For each disconnected group have a unique color assigned.
over 1 year ago in AutoPIPE / Modelling 0 Needs review