When a Joint type and user SIF are inserted, the Sus Tors. Index value will actually be computed in the post processor. In the meantime, AutoPIPE displays a value of "1.00" in the dialog, which can be misleading for the user. It is recommended to change the Value from "1.00" to "Auto" to clarify that this value is calculated automatically (similar to the Code Combination Allowable). Additionally, suggest that the help documentation is updated to reflect the new changes to this field.