Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF
By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.