Elastic Modulus considered for EN 13445-3 should be as per Design temperature
While designing heat exchanger as per EN 13445-3, AutoPIPE Vessel is considering elastic modulus at mean metal temperature but elastic modulus values should be taken at design design temperature. Refer attached snap.