Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 49

"Selection types different" - Develop a permanent solution for this error

https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18879/selection-types-different-message-occurs-when-copy-pasting-to-autopipe Develop a permanent solution for this bug since 2015. Copy and pasting rows fro...
11 months ago in AutoPIPE / Modelling 0 Needs review

Output file should describe number of Warning/Error conditions encountered

Analysis quality will improve if AutoPIPE Output Report (SQO) describes the number of Warning/Error conditions encountered together with a recommendation to view .CHK, .DCHK, .ANL and any other Warning/Error files present. The lack of a recommenda...
about 1 year ago in AutoPIPE / Analysis 0 Needs review

Increase the number of SAM / Support Groups

AS of AutoPIPE 23.00.00.230, the maximum number of unique response spectrums that can be analyzed is 200 [(S1..S10)x 20 support groups per SAM case]. Suggest to Increase the number of SAM and/or Support Groups in order to allow 200+ unique respons...
about 1 year ago in AutoPIPE / Analysis 0 Needs review

Create and Save selection set of node points and beam points

As of July 2023, after making a selection set (highlighted red) it may become unselected when choosing the next command or another location that is not apart of the selection set. The user may need to perform another command / modification to a pr...
about 1 year ago in AutoPIPE / Modelling 1 Needs review

Support Results grids local direction should be user friendly and consistent

Open the results grids, select the support tab, and locate the columns for LocalDir1 - Gap3. Quick what does this refer to: pipe local axis, support local axis? Is this direction consistent across all of the support types (see attached image of Su...
over 1 year ago in AutoPIPE / Reporting 0 Needs review

One insulation layer in DNG export

Please make the insulation layer in DNG export one layer and not one later per segment. This will allow the one layer to turned off in the DNG display.
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Allow stresses from soils to be combined with other pipe stress loads in user defined combinations

Currently ring bending stresses in pipes from soil loads cannot be exported within a separate user-defined load combination (like gravity / thermal / poisson loads etc.) but has to be exported as part of a very specific pre-determined code combina...
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Allow manual entry of wind topographic factor Kzt

No description provided
almost 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Allow import of large coordinates from CAD systems

Currently AutoPIPE have an option to shift the coordinates when importing PCF files with large coordinates (more than 6 digits). Also if this option is not selected, the piping import will fail as the pipe lengths would be messed up. I understand ...
almost 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review