Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 157 of 236

Add capability to model 2 springs in series

Spring hanger arrangement, see attachment.
over 1 year ago in AutoPIPE / Modelling 0 Needs review

Model new piping geometry based on newly established local coordinate system instead of Global coordinate system

Use Case: If The entire model is using plant coordinates thus causing the entire system to be off AutoPIPE's global axis. Then, if the user needs to add new piping geometry it is very difficult to model in AutoPIPE using global coordinates. Users ...
over 1 year ago in AutoPIPE / Modelling 0 Needs review

One Button Z Up Conversion

When exporting a file to a DGN, one can easily click a button to transpose the model from Y up to Z up. It would be very handy if this could be done in the AutoPIPE model itself. Then one could simply click a button to change a file from Y up to Z...
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 7 Future consideration

Bolt Pre Tension

Possibility to declare bolt pre tension (eg, 40% or 50% of bolt SMYS) has to be provided in the Flange check.
almost 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

A single Autopipe file

Similar to APC files, it would be much more convenient if Autopipe packaged all essential sub files during an analysis project and created a single file by default. It would ensure that the user does not make a mistake and stores the wrong files. ...
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 5 Already exists

Color plot: Connected Segments

Provide a color map based on the Connected Segments (Select > Segments > Connected Segments). For each disconnected group have a unique color assigned.
almost 2 years ago in AutoPIPE / Modelling 0 Needs review

Combination Reorganization

In the screenshot in the attached link, for example, i would like to move the highlighted combinations between LC130 and LC131. Does this make sense? As far as I know, the only way to do this is to duplicate LC131 to LC148 and then delete them. Li...
about 4 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
about 1 year ago in AutoPIPE / UI 0 Future consideration

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
8 months ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
8 months ago in AutoPIPE / Reporting 0 Needs review