Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
3 months ago in AutoPIPE / UI 0 Needs review

Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains ...
4 months ago in AutoPIPE / Analysis 0 Needs review

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
2 months ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
2 months ago in AutoPIPE / Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
2 months ago in AutoPIPE / Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
2 months ago in AutoPIPE / Reporting 2 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
3 months ago in AutoPIPE / Reporting 0 Needs review

Stress Isometric: populate isometric title block

Add options to export data from AutoPIPE that will to fill in attribute data for a Stress Isometric title block.
over 1 year ago in AutoPIPE / UI 1 Needs review

Ring Tool - Ability to modify angles in the Ring Tool dialog

When a user defines custom projections in the Ring Tool dialog, and then realizes they need to add an additional angle, it is not possible. The current method requires the user to clear out the custom angles defined and reenter the custom defined ...
about 1 year ago in AutoPIPE / Modelling 0 Needs review

Bring back the Bentley AutoPIPE User Accreditation Program

As per the note in read on the top of this page, please bring back the user accreditation program
9 months ago in AutoPIPE / AutoPIPE Pipe Stress 1 Needs review