Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

AutoPIPE

Showing 143 of 214

Reference Loads - Results Database

Currently, AutoPIPE does not have the option to export reference loads to a .mdb file. I want to be able to easily compare the Reference Loads to their allowable. This is most handy when you have radial nozzles. Please include the allowable loads ...
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
about 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
4 months ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
4 months ago in AutoPIPE / Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
4 months ago in AutoPIPE / Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
4 months ago in AutoPIPE / Reporting 2 Needs review

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
almost 2 years ago in AutoPIPE / UI 0 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
4 months ago in AutoPIPE / Reporting 0 Needs review

Import multiple load cases from pcf files

We are trying to reduce the steps required to edit piping in initial design. We have multiple transients that all have to be accounted for. In order to hold a consistent model, we are trying to make any and all changes in SolidWorks and import int...
5 months ago in AutoPIPE / UI 6 Planned

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
over 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration