Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
6 months ago in AutoPIPE / Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
6 months ago in AutoPIPE / Analysis 0 Needs review

Ring Tool - Ability edit or modify the settings of an existing ring

Users cannot edit or modify existing rings. This is costing significant manhours to redo Ring Placement if the user forgets something during the initial ring placement.
over 1 year ago in AutoPIPE / Modelling 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
6 months ago in AutoPIPE / Reporting 2 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
6 months ago in AutoPIPE / Reporting 0 Needs review

Import multiple load cases from pcf files

We are trying to reduce the steps required to edit piping in initial design. We have multiple transients that all have to be accounted for. In order to hold a consistent model, we are trying to make any and all changes in SolidWorks and import int...
6 months ago in AutoPIPE / UI 6 Planned

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
12 months ago in AutoPIPE / Analysis 0 Future consideration

Second UI Window for docking dialogs, tools and grids

Autopipe has multiple windows, tools, floating windows, grids and other UI Elements. For users that use multiple monitors, The above UI Elements often move around, and re orient themselves. By providing the user with a second UI Application Window...
about 2 years ago in AutoPIPE / AutoPIPE Pipe Stress / UI 1 Future consideration

Evaluate ASME B16.5/47 flanges per ASME BPVC VIII-1 UG-44(b)

ASME B31.3-2022 F312 FLANGED JOINTS suggests using UG-44(b) "for qualifying piping external loadings on welding neck flanges". UG-44(b) is a modification of the very conservative equivalent pressure method.
about 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 2 Future consideration

Add capability to model 2 springs in series

Spring hanger arrangement, see attachment.
over 1 year ago in AutoPIPE / Modelling 0 Needs review