Reference Loads - Results Database

Currently, AutoPIPE does not have the option to export reference loads to a .mdb file. I want to be able to easily compare the Reference Loads to their allowable. This is most handy when you have radial nozzles. Please include the allowable loads ...
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
7 months ago in AutoPIPE / UI 0 Future consideration

When exporting a model, the user should have the ability to select which nodes are exported based on the type of element it represents.

When creating stress isometric drawings, my team typically exports a .dxf file of the AutoPIPE Model. We are only concerned with nodes that represent support locations, however, there is no option to export only support nodes. Having this option a...
over 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
over 1 year ago in AutoPIPE / Modelling 0 Future consideration

Component stress factor and thickness summary table in main UI

A summary table will be presented in the main user interface which will list the components (like shell, head, nozzle, cone body flange etc.) along with the corresponding calculated stresses, allowable stresses, calculated minimum required thickne...
11 months ago in AutoPIPE Vessel 0 Future consideration

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
over 1 year ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
over 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
over 1 year ago in AutoPIPE / AutoPIPE Pipe Stress 2 Future consideration

Second UI Window for docking dialogs, tools and grids

Autopipe has multiple windows, tools, floating windows, grids and other UI Elements. For users that use multiple monitors, The above UI Elements often move around, and re orient themselves. By providing the user with a second UI Application Window...
over 1 year ago in AutoPIPE / AutoPIPE Pipe Stress / UI 1 Future consideration

Evaluate ASME B16.5/47 flanges per ASME BPVC VIII-1 UG-44(b)

ASME B31.3-2022 F312 FLANGED JOINTS suggests using UG-44(b) "for qualifying piping external loadings on welding neck flanges". UG-44(b) is a modification of the very conservative equivalent pressure method.
over 1 year ago in AutoPIPE / AutoPIPE Pipe Stress 2 Future consideration