Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 63

Combination Reorganization

In the screenshot in the attached link, for example, i would like to move the highlighted combinations between LC130 and LC131. Does this make sense? As far as I know, the only way to do this is to duplicate LC131 to LC148 and then delete them. Li...
over 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Group Segments

Add the ability to group a selection of segments to be easily selected
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration

ASME Flange Summary to show both Operating and Seating in separate columns

Currently the results summary will show the worst case for the flange. ASME B16.5 flanges combined with spiral wound gaskets will commonly fail the seating condition check with the ASME division 1 checks. This can be ignored provided the operating...
8 months ago in AutoPIPE / Reporting 0 Future consideration

Allow gap supports with response spectra analysis

Response spectrum analysis is a static equivalent linear analysis to a dynamic earthquake event. AutoPIPE allows the use of V-Stops with gaps for static analysis. The condition of the gap closure and subsequent support loading is determined by eva...
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration

add user define on spring "hot load input" and let the program design spring rate, Cold load and variation checking

No description provided
9 months ago in AutoPIPE / Analysis 0 Future consideration

Hydrotest Pressure Extension

Users can decide whether pressure extension should be considered in static analysis sets, but this is not an option for hydrotest cases. The user is required to consider it with no option to unselect "Pressure Extension" in the "Analysis Sets" int...
9 months ago in AutoPIPE / Analysis 2 Future consideration

Model Square pipe / ducting

Add the ability to model square piping / ducting
over 1 year ago in AutoPIPE / Modelling 1 Future consideration

Add line number attribute to drawing table ISO stress

No description provided
about 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration

Always enable "Use weight factor for bolt/nut weight" when importing a flange

When importing a PCF file please allow for the option to enabler "Use weight factor for bolt/nut weight" for flanges
about 3 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration

Improve reference loads dialog

Add a toggle between X/Y/Z and axial/shear/bending/torsion for forces and moments in the reference loads dialog. Many allowables for connections are given in terms of total shear load or bending moment. It is not possible to use the current refere...
over 1 year ago in AutoPIPE / AutoPIPE Pipe Stress / UI 0 Future consideration