AccuDraw functionality to be able to select, place and move components

This will be a huge improvement with the ability to interact with Autopipe. Currently, users have to use a coordinate system, and map out changes to the Autopipe Mode. A feature similar to Accudraw in Microstation would significantly improve the a...
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

On screen Code Stress Pass/Fail Indicator

During the development of pipe design, one may need to iteratively. make small changes, and check the impact on stress, Forces, Restraint forces, etc. It would save a lot of time if there was an indicator on the default main UI that states the hig...
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 4 Future consideration

Redesign Input Grid

The current input grid is difficult to read and navigate between all the tabs. The UI elements shall be redesigned to facilitate improved navigation and data input.
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 1 Future consideration

Flexible elements displacement results in element local axes

having flexible elements displacements results reported in local element axes, provides a better way to quantify relative end displacements and avoids doing global to local axes transformation out of the software. Amount of end and intermediate di...
about 1 year ago in AutoPIPE / AutoPIPE Pipe Stress 1 Already exists

Add trunnions and connected supports to Stress Isometric

Stress ISOmetric, I would like to see the trunnions shown along with their attached supports This will definitely save time having to annotate stress isos to show the missing pipe supports with the trunnions.
about 4 years ago in AutoPIPE / AutoPIPE Pipe Stress 2 Future consideration

"Selection types different" - Develop a permanent solution for this error

https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18879/selection-types-different-message-occurs-when-copy-pasting-to-autopipe Develop a permanent solution for this bug since 2015. Copy and pasting rows fro...
about 1 year ago in AutoPIPE / Modelling 0 Needs review

Modeling soils in AutoPIPE should be simplified

In my opinion modeling of soils in AutoPIPE takes to much time and could/should be simplified. For selected part of the model, including simultanously vertical, horizontal or inclined segments, there are four geometrical methods to define a terrai...
over 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 2 Future consideration

Output file should describe number of Warning/Error conditions encountered

Analysis quality will improve if AutoPIPE Output Report (SQO) describes the number of Warning/Error conditions encountered together with a recommendation to view .CHK, .DCHK, .ANL and any other Warning/Error files present. The lack of a recommenda...
about 1 year ago in AutoPIPE / Analysis 0 Needs review

Write as many Error messages as possible to *.ANL file

Currently Error messages appear on screen while interactively using AutoPIPE. If doing Batch processing Error messages never appear! If an Error message can be displayed on the screen it can also be written to the *.ANL file. Error conditions that...
over 1 year ago in AutoPIPE / Reporting 0 Planned

Increase the number of SAM / Support Groups

AS of AutoPIPE 23.00.00.230, the maximum number of unique response spectrums that can be analyzed is 200 [(S1..S10)x 20 support groups per SAM case]. Suggest to Increase the number of SAM and/or Support Groups in order to allow 200+ unique respons...
over 1 year ago in AutoPIPE / Analysis 0 Needs review