Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 61

Add Victaulic fitting

AutoPIPE can model a Victaulic fitting using a number of approach mentioned here . However this is a very difficult and demanding process. Not to mention, that in some case there are converging issues related to multiple Flexible joints on connect...
about 1 year ago in AutoPIPE / Modelling 2 Future consideration

Add a Bolted Domed end

Possibility to add a Bolted Domed end according EN 13445.3 clause 12
9 months ago in AutoPIPE Vessel 0 Future consideration

Lifting accesoires: handled independently.

They appear in the list of components, the 2D and 3D view. Local loads for them can be checked in Design Component. Their welds appear in the weld map.
12 months ago in AutoPIPE Vessel 1 Future consideration

Add a toggle button in segments grid to apply a transparency visual plot

Working with existing or future segments in large systems, it would be great to have a option to change their segments plot (like adding transparency). Something similar to older software like Triflex (see attached image).
7 months ago in AutoPIPE / UI 2 Future consideration

Elastic Modulus considered for EN 13445-3 should be as per Design temperature

While designing heat exchanger as per EN 13445-3, AutoPIPE Vessel is considering elastic modulus at mean metal temperature but elastic modulus values should be taken at design design temperature. Refer attached snap.
about 1 year ago in AutoPIPE Vessel 0 Future consideration

CLAMP CONEXIONS

Just as you can include flanges (EN-DIN-ASME) in the connections, include CLAMP connections (ASME BPE - DIN32676) that are very common in the pharmaceutical industry.
11 months ago in AutoPIPE Vessel 0 Future consideration

Load Combinations -seismic and wind load factors should be adjustable by user

Factors multiplying the wind and seismic loads need to be adjustable by user. Example below in red box shows Load combinations for wind load. Currently this combination is hardcoded in the program.
11 months ago in AutoPIPE Vessel 0 Future consideration

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
6 months ago in AutoPIPE / Analysis 0 Future consideration

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
6 months ago in AutoPIPE / Reporting 1 Future consideration

Support Detail Fig # and Allowable Support Load Ratings

Ensuring support info (gaps, friction, stiffness) is correct and reviewing support results are some of the more time consuming tasks. It would be very handy to be able to set up a library of support detail figure numbers with allowable load ratings.
almost 2 years ago in AutoPIPE / AutoPIPE Pipe Stress 0 Future consideration