Body Flange Thickness (g0) Vs Shell thickness - Vs Allowable values

When we have a bogy flanged implemented in a cylindrical shell we need to define a thickness for shell and a thickness for flange (g0). Normally the both thickness are the same and the software only take into account the shell value for internal p...
5 months ago in AutoPIPE Vessel 0 Needs review

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
about 2 years ago in AutoPIPE / Analysis / AutoPIPE Pipe Stress 0 Future consideration

Consider the external pressure for ASME B31.8 / B31.4 offshore

As a subsea engineer using AutoPipe for modelling spools and jumpers, it is frustrating and misleading that AutoPipe does not account automatically for external pressure in all codes.
8 months ago in AutoPIPE / Analysis 2 Needs review

Expansion Bellows - Option to choose the "as formed" and "Annealed" bellows

Need to add an option to consider "as formed" and "annealed" bellow This will impact on following parameters and user can choose as per their requirements, ASME Km & Kg factor ASME factor 2.3 or 0.75 for Sy* EJMA Cm factor
10 months ago in AutoPIPE Vessel 0 Needs review

Allow a calculation full of liquid

A tall vessel or column is normally designed with a particular liquid level. It would be very helpful if a new user case can be defined allowing to calculate full of liquid (which is not water, it is not the same as hydrotest).
about 1 year ago in AutoPIPE Vessel 0 Needs review

Nozzle loads on supports

When it is added local loads for nozzles, these loads should be taken in consideration for the support calculation and fundation loads considering the location and orientation of nozzle, for example, Nozzle A located on top head has local loads su...
about 1 year ago in AutoPIPE Vessel 0 Planned

Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
7 months ago in AutoPIPE / UI 0 Needs review

Jacket closure calculation according to PD 5500

We have noticed that the software systematically considers all jackets as type 2 in the jacket closure calculation following PD 5500. We need you to integrate the concept of type 1 jackets in the next version to facilitate support for this type of...
over 1 year ago in AutoPIPE Vessel 1 Needs review

Add Autodesk Inventor as an export option.

To generate parts, assembly and drawings with i logic .
over 1 year ago in AutoPIPE Vessel 0 Planned

Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains ...
7 months ago in AutoPIPE / Analysis 0 Needs review