Flange and head calculation

This option is only available when floating head heat exchanger is calculated, for normal vessels it is not possible to use a crown (hemispherical) head welded direct into a flange without knuckle or straight flange.
over 1 year ago in AutoPIPE Vessel 0 Needs review

Add Greek seismic code EAK 2000 and its 2003 ammedments

Greece is a country with high seismic behaviour. Many industrial projects are on going in Greece, it would be beneficial to add Greek seismic code.
over 1 year ago in AutoPIPE Vessel 0 Needs review

Ring Tool - Ability edit or modify the settings of an existing ring

Users cannot edit or modify existing rings. This is costing significant manhours to redo Ring Placement if the user forgets something during the initial ring placement.
over 1 year ago in AutoPIPE / Modelling 0 Needs review

Component stress factor and thickness summary table in main UI

A summary table will be presented in the main user interface which will list the components (like shell, head, nozzle, cone body flange etc.) along with the corresponding calculated stresses, allowable stresses, calculated minimum required thickne...
over 1 year ago in AutoPIPE Vessel 0 Future consideration

Codap - Opening with pad according to C5.1.4b13

Nozzles design: Please provide an opction that considers the alternative calculation method when there is an insert forged pad
over 1 year ago in AutoPIPE Vessel 0 Needs review

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
6 months ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
6 months ago in AutoPIPE / Reporting 0 Needs review

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
about 1 year ago in AutoPIPE / Analysis 0 Future consideration

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
6 months ago in AutoPIPE / Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
6 months ago in AutoPIPE / Reporting 2 Needs review