Jacket closure calculation according to PD 5500

We have noticed that the software systematically considers all jackets as type 2 in the jacket closure calculation following PD 5500. We need you to integrate the concept of type 1 jackets in the next version to facilitate support for this type of...
over 1 year ago in AutoPIPE Vessel 1 Needs review

Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
7 months ago in AutoPIPE / UI 0 Needs review

Add Autodesk Inventor as an export option.

To generate parts, assembly and drawings with i logic .
over 1 year ago in AutoPIPE Vessel 0 Planned

Thickness required for infternal pressure - each component

Add a dialog box to see the required thickness for internal pressure for each component based on temperature and internal pressure. It is applicable for heads, shell, nozzle necks, body flanges - Like picture enclosed.
about 1 year ago in AutoPIPE Vessel 0 Future consideration

Possibilité d'incorporer des tubulure rectangle/carrée

Nous avons très régulièrement des demandes client pour calculer des appareils suivant différents codes, avec des tubulures carrées et/ou rectangulaires. Est'il possible d'intégrer ce genre de tubulures dans autopipe vessel?
about 2 months ago in AutoPIPE / Modelling 0 Needs review

Calcul suivant CODAP - Partie C12

Lors de calcul de double enveloppe, nous avons constaté qu'AUTOPIPE VESSEL n'intégre pas la partie C12 du CODAP. C'est un manque important dès qu'il y a double enveloppe. Nous supposons également que si ce manque est existant au niveau du CODAP il...
about 2 months ago in AutoPIPE Vessel 0 Needs review

Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains ...
8 months ago in AutoPIPE / Analysis 0 Needs review

Add Button on Help Tab to Download Most Recent Version

Each time I need to update or search to see if there is an update, I spend too much time trying to figure out how to wade through all the various avenues Bentley has to find the most recent version of AutoPIPE, and if I'm behind, then download the...
2 months ago in AutoPIPE / UI 2 Planned

Autosave the file after 1 minute

Kindly refer to the discussion in regard to the case no. CS0345238, regarding introducing autosave option after every 1 min or less. Similar feature is available in other stress analysis software can't same be availed in Auto PIPE as well, because...
2 months ago in AutoPIPE / AutoPIPE Pipe Stress 0 Needs review

Flange analysis EN 1591-1

Include EN1591-1 calculations methodology for flanges / flange leakage Look through EN 13445-3 Annex G - Alternative design rules for flanges and gasketed flange connections
almost 4 years ago in AutoPIPE / AutoPIPE Pipe Stress 13 Planned